LIMITATION OF THE INDUCED INTERFERENCES ON THE CIRCUIT
4.2 LIMITATION OF THE INDUCED INTERFERENCES ON THE CIRCUIT
- Weave and screen the signal conductors
- Put on the ground to just a one extremity the weak signal conductors screen to a low frequency
- When the weak signal conductors and the noises conductors are in the same connectors, separate them interposing between them the earth connectors.
- Take the signal conductors screen across the connectors on the separated pin.
- Avoid the common earth conductors between the equipments to high level and those a low level
- Keep separated the electrics circuits earth from the metallics structures earth
- Keep the earth conductors as shorter as possible
- Maintain the source and the cargo balanced towards the earth
- Enclose all the sensibles circuits in the screening zones.
- Filtrate or decouple the conductors that entry in the screened bin
- Maintain as shorter as possible the termination conductors of the cables screens
- Avoid the grounding' mash reducing the area to the minimum.